Back to top
Emissivity Measurement
Emissivity Measurement

Emissivity Measurement

MOQ : 1 Unit

Emissivity Measurement Specification

  • Measurement Range
  • Emissivity 0.10 to 1.00
  • Temperature Range
  • 0C to 200C
  • Model No
  • EM-01
  • Core Components
  • Sensor, Controller, Display Module
  • Capacity
  • 1 Unit
  • Automation Grade
  • Semi-Automatic
  • Feature
  • High Precision, User-Friendly Interface, Portable
  • Frequency
  • 50 Hz
  • Accuracy
  • 0.01 Emissivity
  • Power Source
  • Electric
  • Voltage
  • 220 V AC
  • Equipment Materials
  • SS 304 Stainless Steel
  • Type
  • Emissivity Measurement Instrument
  • Usage
  • Laboratory, Industrial Testing
  • Display Type
  • Digital
  • Dimension (L*W*H)
  • 270 mm x 190 mm x 150 mm
  • Weight
  • 3 kg
  • Operating Humidity
  • 10% to 80% RH, non-condensing
  • Data Output
  • USB/RS232 Interface
  • Surface Type Compatibility
  • Polished, Coated, and Uncoated Surfaces
  • Response Time
  • <2 Seconds
  • Display Resolution
  • 0.001
  • Calibration
  • Factory Calibrated
  • Storage Temperature
  • -10°C to 60°C
  • Sensor Type
  • Infrared Sensor
  • Operating Temperature
  • 5°C to 45°C
  • Power Consumption
  • <20 W
 
 

About Emissivity Measurement



Experience superb precision with our EM-01 Emissivity Measurement Instrument, engineered for elite laboratory and industrial testing. This first-class device, crafted from monumental SS 304 stainless steel, offers high savings in operation through its low power consumption and user-friendly interface. In demand among exporters, manufacturers, and suppliers throughout India, the EM-01 delivers data output via USB/RS232 with a stellar response time under 2 seconds. Compatible with polished, coated, and uncoated surfaces, its portable design, factory calibration, and exceptional accuracy make it the premium choice for high-stakes applications.

Special Features and Commercial Applications

The EM-01 Emissivity Measurement Instrument boasts advanced features such as high precision (accuracy 0.01), a digital display with superb resolution (0.001), and compatibility with various surfaces. Widely used in laboratories and industrial settings, it serves for research, quality control, and process monitoring. Its portable build and semi-automatic operation make it a first-class solution for those who demand monumental reliability and efficiency in emissivity measurement tasks.


Certifications, Quotation, and Market Delivery

Our EM-01 instrument is handed over after premium factory calibration to ensure optimal reliability. Quotation is provided for both domestic and international export scenarios, with FOB port options available for seamless delivery. Serving the main domestic markets across India, the product's certifications and adherence to strict standards make it a trusted resource among scientific and industrial professionals. Exceptional support and comprehensive documentation are delivered with each unit.


FAQ's of Emissivity Measurement:


Q: How does the EM-01 ensure precise emissivity measurement?

A: The EM-01 instrument achieves superior accuracy ( 0.01 emissivity) through advanced infrared sensor technology, premium factory calibration, and a digital display with 0.001 resolution, delivering first-class measurement results.

Q: What surfaces can the EM-01 measure emissivity on?

A: This device is compatible with polished, coated, and uncoated surfaces, making it ideal for both laboratory experiments and varied industrial applications requiring monumental flexibility.

Q: When is the EM-01 best used in industrial settings?

A: The instrument is best utilized when quick, reliable emissivity measurement is essential, especially within temperature ranges of 0C to 200C and where high accuracy is crucial in process testing or quality control.

Q: Where can I request a quotation or arrange delivery of the EM-01?

A: Quotations for the EM-01 can be requested through our sales team, and delivery includes options for FOB port in India to meet customer preferences for local or export markets.

Q: What is the process for calibrating and operating the EM-01 unit?

A: The EM-01 comes factory calibrated for immediate, superb use. Operation is semi-automatic, with data output via USB/RS232 and simple controls for user-friendly interaction.

Q: How does using the EM-01 benefit laboratory and industrial professionals?

A: By choosing this elite instrument, professionals gain high savings through efficient power use, reliability, and portability, all of which enhance testing protocols and measurement accuracy.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Mechanical Engineering Lab Category

Static and Dynamic Balancing Apparatus

Static and Dynamic Balancing Apparatus

Minimum Order Quantity : 1 Unit

Measurement Range : Up to 1 kg Eccentric Mass

Temperature Range : Ambient

Usage : Static and Dynamic Balancing of Rotors

Model No : SDB01

Type : Mechanical Laboratory Apparatus

Motorised Gyroscope

Motorised Gyroscope

Minimum Order Quantity : 1 Unit

Measurement Range : 0500 RPM

Temperature Range : Ambient

Usage : Physics Laboratory Experiments

Model No : TG101

Type : Laboratory Instrument

JET IMPACT APPARATUS

JET IMPACT APPARATUS

Minimum Order Quantity : 1 Piece

Measurement Range : Force range up to 10 N

Temperature Range : Ambient

Usage : Educational laboratory, for studying impact of jet

Model No : JETIMP01

Type : Hydraulic Laboratory Apparatus

Critical heat Flux Apparatus

Critical heat Flux Apparatus

Minimum Order Quantity : 1 Unit

Measurement Range : Up to critical heat flux limit of the test specimen

Temperature Range : Ambient to 200C

Usage : Engineering and Thermal Laboratory Experiments

Model No : CHF101

Type : Laboratory Critical Heat Flux Apparatus