Back to top
Muffle Furnace
Muffle Furnace

Muffle Furnace

Muffle Furnace Specification

  • Measurement Range
  • Up to 1200C
  • Accuracy
  • 2C
  • Automation Grade
  • Manual
  • Core Components
  • Heating Element, Insulation, Thermal Regulator
  • Feature
  • Uniform Heating, Energy Efficient, Fast Heat-Up
  • Capacity
  • 2 L
  • Model No
  • MF-1200
  • Frequency
  • 50 Hz
  • Temperature Range
  • Ambient to 1200C
  • Voltage
  • 220-230 V
  • Power Source
  • Electric
  • Equipment Materials
  • Mild Steel Body with Powder Coating, Ceramic Insulation
  • Type
  • Laboratory Furnace
  • Usage
  • Laboratory, Industrial Applications
  • Display Type
  • Digital
  • Dimension (L*W*H)
  • 305 mm x 125 mm x 125 mm (Inner chamber)
  • Weight
  • 15 kg (approx.)
  • Safety Features
  • Overtemperature Protection, Door Interlock Switch
  • Controller Type
  • Digital PID Controller
  • Door Type
  • Front Opening, Ceramic Fiber Lined
  • Heating Element Material
  • Kanthal A1 Wire
  • Thermocouple
  • K-Type
  • Heat-Up Time
  • Approx. 30 min to max temp
  • Chamber Material
  • High Temperature Ceramic
  • Exterior Finish
  • Epoxy Powder Coated
  • Maximum Power Consumption
  • 2.5 kW
 
 

About Muffle Furnace



Highlighted as a hot-selling laboratory furnace, the MF-1200 Muffle Furnace is a monumental blend of precision and reliability. Featuring a meritorious Kanthal A1 wire heating element and a gilt-edged ceramic fiber lining, it ensures rapid heat-up and exceptional temperature uniformity. The front-opening door, robust mild steel construction, digital PID controller, and advanced safety features, like overtemperature protection and door interlock switch, make it ideal for demanding applications. Order this energy-efficient, fast-heating solution for premium results in laboratories and industrial sectors across India.

Features, Uses, and Areas of Application

The MF-1200 Muffle Furnace stands out for its uniform heating, energy efficiency, and fast heat-up capability, reaching temperatures up to 1200C with 2C accuracy. Used for ashing, sintering, heat treatment, and material testing, it finds application in laboratories, research facilities, and industrial environments. Its advanced thermal regulation and ceramic insulation ensure safety and reliability, making it a preferred choice for professionals seeking precision and efficiency in thermal processes.


FOB Port, Sample Policy, and Export Markets

Premium shipment services are offered with FOB Port delivery from India. Samples are handed over according to mutually agreed policies to ensure clients receive optimal hands-on experience. Main export markets include Asia, Africa, the Middle East, and Europe, where timely delivery and quality assurance are valued. The furnace is manufactured and supplied by a leading exporter, guaranteeing meritorious standards for international clients seeking dependable laboratory solutions.


FAQ's of Muffle Furnace:


Q: How does the MF-1200 Muffle Furnace maintain temperature accuracy during operation?

A: The MF-1200 utilizes a digital PID controller and K-Type thermocouple, ensuring precise temperature regulation within 2C, offering reliable results for laboratory and industrial processes.

Q: What safety features are integrated into this muffle furnace?

A: Safety is prioritized with overtemperature protection and a door interlock switch, safeguarding users and maintaining operational integrity during heating cycles.

Q: Where can the MF-1200 Muffle Furnace be used?

A: This furnace is ideal for laboratories, research institutes, and various industrial applications, including ashing, sintering, and material analysis processes.

Q: What is the process for ordering and delivery of samples for export clients?

A: Samples are handed over as per the agreed sample policy, and delivery is managed through the designated FOB port to provide timely, secure shipment to export markets.

Q: What benefits does the Kanthal A1 wire heating element offer?

A: Kanthal A1 wire enables quick heat-up, high reliability, and prolonged operational life, ensuring efficient and uniform heating for critical laboratory applications.

Q: When does the furnace reach its maximum temperature?

A: The MF-1200 typically heats up to its maximum temperature of 1200C within approximately 30 minutes, allowing for prompt initiation of thermal processes.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Laboratory Scientific Equipments Category

Analytical Balance

Analytical Balance

Usage : Laboratory precision weighing

Equipment Materials : Stainless Steel platter, ABS Housing

Voltage : 220V

Temperature Range : 5C to 40C

Core Components : Weighing sensor, microprocessor, display

Automation Grade : Automatic

Supervision Software: Pilot for Windows

Supervision Software: Pilot for Windows

Usage : Video Monitoring, Surveillance Control

Equipment Materials : Digital (Software Only)

Voltage : Standard PC Power (110240V AC)

Temperature Range : 0C to 60C

Core Components : Software Application, User License

Automation Grade : Fully Automatic

Hot Air Oven

Hot Air Oven

Usage : Laboratory Drying and Sterilization

Equipment Materials : Mild Steel Body with Powder Coating

Voltage : 230V AC

Temperature Range : 50C to 250C

Core Components : Heater, Digital Controller, Blower

Automation Grade : Semi Automatic

Aniline Point Apparatus

Aniline Point Apparatus

Usage : Determining aniline point of petroleum products as per ASTM D611

Equipment Materials : Borosilicate Glass, Stainless Steel, Cast Iron (where applicable)

Voltage : 220240 V AC

Temperature Range : Up to 200C

Core Components : Heating Bath, Sample Flask, Thermometer, Stirrer, Transparent Shield

Automation Grade : Manual